Battery Configurations
975-0012-01-02 Rev A B–11
Connect to inverter To connect to the inverter:
1. Connect a cable from the positive terminal of the first battery string to the
inverters positive DC terminal (via a fused device).
2. Connect the negative terminal of the last battery string to the negative
terminal of inverters DC terminal.
Figure B-6
Battery Wiring 24-volt - Parallel Configuration - Step 3
Important:
Connecting the positive and negative wires to the inverter from different
strings ensures a balanced charge/discharge through the batteries, resulting in longer run
times and improved battery life.
+
6 V 6 V
+ +
6 V 6 V
+
6 V 6 V
6 V 6 V
+
24 V INVERTER
(Tot al bat tery capacit y = 200 Ah)
+ + +
+
Connection from Series String 2 to
inverter's negative (–) terminal
Series String 2
Series String 1
Connection from Series String 1
to inverter's positive (+) terminal
Each battery's amp-hour
rating is 100 Ah.